Update History for the Software OpTra®Dent



The following changes have been implemented with the release 1.1.5.3098 (including hotfix) of 12/07/2018:


New Features

  • Implementation of encryption and data integrity check for generated files during export and import of patient data and examinations
  • Implementation of a synchronization button within CAR (Bite register/Joint space) for a centrically synced zoomable representation of the target positions
  • Implementation of a remote maintenance interface to modify exposure time of Freecorder®BlueFox cameras
  • Display an info dialog after clicking the button “Joint Space Evaluation” within examination “TMJ Examination” to make sure that the bite registration error has been eliminated with CAR (Bite register) beforehand and disable displaying the previous info dialog to make sure that the CAR device is at zero position

Optimizations

  • Improved representation (window sizes and starting points) during recording of single measurements within measurement view
  • Improved representation during recording and playback of single measurement “Occlusal distance” within measurement view and detail view
  • Representation of measurement data in the chosen display mode during playback
  • Display a notice within technical sheet to make sure that the CAR device is at zero position during articulation of the upper jaw model
  • Adjusted preset logout time to 30 min

Bugfixes

  • Prevention of software crash after clicking the button “Save new Revision” with incompletely loaded data within technical sheet
  • Disabled the menu button in measurement mode and CAR (Bite register/Joint space)
  • Disabled the 2-part, 4-part and 6-part view buttons within measurement view of single measurement “Occlusal distance”
  • Corrected disabling of data exchange and start from the software byzz®nxt via the VDDS-media®-interface
  • Corrected adoption of patient master data (order of first and last name) from practice management systems via the VDDS-media®-interface
  • Reduced CPU load and recovery of the image data stream in case of an outage of one or more Freecorder®BlueFox cameras
  • Saving of recorded measurement data before automatic logout

Hotfixes

  • Prevention of software crash while printing the technical sheet, joint space evaluation and CAR (Bite register/Joint space) and prevention of display errors while printing and sending the joint space evaluation

Privacy Policy for the Software Support Using TeamViewer & Download Update Version

For the software support using TeamViewer, the privacy policy has to be present in written form at the Dental Innovation GmbH.

For that, print out the following privacy policy and send it signed to the stated address. If you need the form in english, please contact us.

Privacy Policy »

Please confirm that you have read the informations regarding our privacy policy to unlock the download link.

Please hold your Freecorder®BlueFox serial and license number ready for the installation.


MD5 Checksum: 23819009e9abbaec7557bd707b607014



The following changes have been implemented with the release 1.1.4.2799 of 12/02/2018:


New Features

  • Implementation of two measurement modes with fully automatic footswitch
  • New design of dialog boxes
  • Implementation of a repeat button within detail view to play measurement data in a loop
  • Display an info dialog after clicking the button “New Examination” within examination overview if there is no connection to the Freecorder®BlueFox

Optimizations

  • Improved performance while saving patient database
  • Improved performance during recording and playback of single measurement “Occlusal distance”
  • Consistent representation of user interface within CAR (Bite register/Joint space)
  • Consistent navigation and visualization of selected single measurement from measurement view into detail view
  • Improved calculation of sanity check for mediotrusion measurements
  • Improved calculation of sanity check for FastLink®assembly table values
  • Consistent representation of FastLink®assembly table values correct to one decimal place within measurement view, detail view and technical sheet

Bugfixes

  • Saving of values set within joint space evaluation and technical sheet when exiting the software and selecting menu items
  • Disabling the button “Proceed” within adjustment view after clicking the button “CAR (Bite register)” within protocol/detail view if there is no connection to the Freecorder®BlueFox
  • Corrected disabled saving of empty examinations
  • Corrected faulty navigation within protocol view when double-clicking the scroll button

The following changes have been implemented with the release 1.1.3.2486 (including hotfix) of 12/10/2017:


New Features

  • New concept for joint space evaluation
  • New measurement protocol “mastication” for recording chewing cycles
  • Implementation of VDDS-media®-interface and support of data exchange with byzz®nxt
  • Implementation of remote maintenance interface for software support with TeamViewer
  • Extension of recording time for single measurements up to 60 s (fixed preset of 120 s for “mastication” measurements)
  • Display the remaining recording time during single measurements
  • Input field for comments during single measurements within measurement view
  • Display an info dialog in case of unsuccessful software activition

Optimizations

  • Improved performance during recording, representation and editing of measurement data
  • Improved performance while loading patient database
  • Visual highlighting of manually added single measurements within an examination
  • Consistent color display within joint space evaluation and CAR (Bite register/Joint space)
  • Consistent representation of linked measurements within detail view, technical sheet and CAR (Bite register/Joint space)
  • Values are printed on white background inside CAR (Bite register/Joint space)
  • Improved calculation of articulator values for SAM2/SAM3
  • Disabled switching of active examinations into a different examination
  • Disabled deletion of added single measurements after a finished examination
  • Disabled saving of empty examinations
  • Display an info dialog if migrating the database is required after an update

Bugfixes

  • Prevention of software crash and display of an info dialog after clicking the button “CAR (Bite register)” and the absence of at least one linked single measurement “Discluded protrusion” respectively “Position measurement with bite registration”
  • Prevention of software crash after changing language to english and import of patient data
  • Prevention of software crash and display of an info dialog after saving single measurements with a recording time of less then 60 ms
  • Blocking of added single measurements in case of active examination with invalid hinge axis
  • Preservation of validity for hinge axis measurements when changing from detail to measurement view
  • Corrected transfer of left medial joint space values within “TMJ Examination” to joint space evaluation
  • Corrected calculation of linked single measurements

Hotfixes

  • Corrected GUI within joint space evaluation with regards to the display resolution

The following changes have been implemented with the release 1.1.2.1790 of 22/12/2016:


New Features

  • Display of OpTra®Dent links in the windows start menu
  • Display of the current version number as well as date and time in the titlebar of the main window
  • Anatomical orientation of all graphs (positive directions: caudal, medial, ventral)
  • Display of selected Protrusion curve (discluded) from the technical data sheet in CAR (Joint Space)
  • Adjustment of visualization in CAR (Joint Space) to CAR (Bite register)

Bugfixes

  • Printing and mailing of data in CAR (Bite register/Joint Space) possible during inactive measurement

The following changes have been implemented with the release 1.1.1.1580 of 15/07/2016:


New Features

  • A comment field was added to every measurement
  • VDDS patient data import from different office management systems is now availabe
  • Printing and sending via Mail is now possible in CAR (Bite register), CAR (Joint Space) and joint space evaluation
  • The FastLink®Assembly Table values are shown while measuring (requires a successful hinge axis measurement)
  • In the user settings for curve start and end point decimal values are now a valid input

Bugfixes

  • Starting a measurement with the foot pedal is no longer possible when the measurement button is disabled
  • Crash when measuring with bite registration was fixed
  • Correction of measuring units in the user settings

© 2018 Dental Innovation GmbH